ZX3100 
Sound Level Analyzer

Take a closer look.

Hardware Features
Number of Channels
1
Microphone Type
ZX 1025
Preamplifier Type
ZX 1901E (LEMO connector)
Bluetooth
Yes
GPS
N/A
Display
2.4 inch, resolution:240x320
Data Interface
Blutooth, IO Protocol, USB-C
Data Storage
4 GB internal (up to 64 GB TF Card)
功耗(基本功能)
2W ~ 6W
Battery type
4*AA alkaline batteries
Calendar Clock
Monthly error less than 1 minute with battery
Operating time
up to 28 hours
Operating temperature range
-20 °C〜60 °C
Humidity range
20 %〜90 %
Atmospheric pressure
65 kPa〜108 kPa
Weight
Approx. 340g
Size
Overall dimensions (mm): 250×76×33;
​Sound Measurements Features
Total Measurement range
20 dB(A)〜140 dB(A); 30 dB(C)〜140 dB (C); 35 dB(Z)〜140 dB (Z)
Internal noise
< 13 dB(A) Leq
microphone and preamplifier sensitivity
-28 dB Note: Sensitivity is referenced at 0 dB with 1V/Pa. Unless otherwise specified below, all references to sensitivity pertain to the standard configuration.
Frequency range
10 Hz~20 kHz
Weighting filters
Parallel A, C, Z weighting
Time constants
Parallel F (fast), S (slow), I (impulse), I10
Exchange rates
N/A
Measurement Time
1 second to 99 hours
Total value integration
Peak C Sound Level Measurement Range: 60 dB~143 dB Measurement Indicators: Lxyp, Lxeq,t, Lxeq,T, Lxmax, Lxmin, LxE, Lxpeak, E, SD Note: x represents A, C, Z; y represents F, S, I, I10;
Statistics (Optional)
Statistical Analysis Indicators: Lxyp, Lxeq,T, Lxymax, Lxymin, LxN, LE, SD. Note 1: x represents A, C, Z; y represents F, S, I; N represents 5, 10, 50, 90, 95
1/1 octave (Optional)
N/A
1/3 octave (Optional)
N/A
FFT (Optional)
N/A
Reverberation time (Optional)
N/A
STIPA (Optional)
N/A
Audio recording
- Selectable Sampling Rates: 12 kHz, 24 kHz, 48 kHz; - 16-bit or 24-bit precision, WAV or MP3 format; - Recording time is unlimited until memory is full (when recording continuously, the recording files are split into one file per hour); - Recordings can be played back on the device or on a PC;
Voice coments
N/A
Standards
Class 1:IEC 61672-1:2013;
Class 1:IEC 61260-1:2014;
Applications
Sound Measurements
Environmental Noise