top of page

ZX3300
Sound Level Analyzer

Take a closer look.

Get the highlights.

AWA6292测面图.2.png

Class 1:IEC61672-1:2013

Class 1:IEC61260-1:2014

Standards
Class 1:IEC 61672-1:2013;
Class 1:IEC 61260-1:2014;
IEC 61252:2017
Applications
Sound Measurements
Environmental Noise
Occupational Noise
Building Acoustics
​Sound Measurements Features
Total Measurement range
20 dB(A)〜143 dB(A); 25 dB(C)〜143 dB (C); 30 dB(Z)〜143 dB (Z)
Internal noise
< 18 dB(A) Leq
microphone and preamplifier sensitivity
-28 dB Note: Sensitivity is referenced at 0 dB with 1V/Pa. Unless otherwise specified below, all references to sensitivity pertain to the standard configuration.
Frequency range
10 Hz~20 kHz
Weighting filters
Parallel A, C, Z weighting
Time constants
Parallel F (fast), S (slow), I (impulse)
Exchange rates
3, 4, 5, 6
Measurement Time
1 second to 96 hours
Total value integration
Peak C Sound Level Measurement Range: 60 dB~146 dB Measurement Indicators: Lxyp, Lxeq,t, Lxeq,T, Lxmax, Lxmin, LxN, Lxpeak, SEL, SD Note: x represents A, C, Z; y represents F, S, I; N represent5,10, 50, 90, 95
Statistics (Optional)
Analysis Mode: Single, 24hours. Statistical Analysis Indicators: Lxyp, Lxeq,T, Lxmax, Lxmin, LxN, SD, SEL. 24h Mode Analysis Indicators: Lxyinst, Lxeq,T, Lxmax, Lxmin, LxN, SD, SEL, Ld, Ln, Ldn; Note 1: x represents A, C, Z; y represents F, S, I; N represents 5, 10, 50, 90, 95(customize up to 10 values between 1 to 99)
1/1 octave (Optional)
Filter Type: Parallel (real-time) octave, G=10^(3/10). Complies with Standards: Class 1: IEC 61260:1995, MOD; Filter Center Frequencies: From 8 Hz up to 16 kHz Time Weighting: Fast (F) and Slow (S). Real-time Analysis: Parallel computation of all center frequencies with A, C, Z weightings. Dynamic Range: Greater than 90 dB (Z). Main Measurement Indicators: Instantaneous Sound Pressure Level (Lp) in bands, Maximum (Max), Minimum (Min), and Equivalent Continuous Sound Pressure Level (Leq,T).
1/3 octave (Optional)
Filter Type: Parallel (real-time) one-third octave, G=10^(3/10). Complies with Standards: Class 1: IEC 61260:1995, MOD; Filter Center Frequencies: From 5 Hz up to 20 kHz. Time Weighting: Fast (F) and Slow (S). Real-time Analysis: Parallel computation of all center frequencies with A, C, Z weightings, including custom frequency weightings. Dynamic Range: Greater than 90 dB (Z). Main Measurement Indicators: Instantaneous Sound Pressure Level (Lp) in bands, Maximum (Max), Minimum (Min), and Equivalent Continuous Sound Pressure Level (Leq,T).
FFT (Optional)
Pre-FFT Weighting: A, C, Z weightings. Time Weighting: Fast (F) and Slow (S), optional. FFT Analysis Lines: up to 3385 lines. Analysis Frequency Upper Limit: up to 20k Hz Bandwidth per Line Bp: 5.9 Hz Window Functions: Flat-top, Hanning, and Rectangular windows selectable. Measurement Indicators: Fast time-weighted instantaneous values under each spectrum line, slow time-weighted instantaneous values, maximum and minimum sound pressure levels (Max/Min) under the spectrum line, and equivalent continuous sound pressure level (Leq,T), with measurement duration (Tm).
Reverberation time (Optional)
ISO 3382-2:2008;
STIPA (Optional)
- IEC 60268-16;ISO 3382-1; ISO 3382-2; ISO 3382-3; ISO 1996; - Measurement Indices:Leq、MTI、STI; - Single Record Time:15 s; - Recording Precision: Sampling rate 48 kHz, 32-bit; - Frequency Points: 125 Hz, 250 Hz, 500 Hz, 1000 Hz, 2000 Hz, 4000 Hz, 8000 Hz;
Audio recording
- Selectable Sampling Rates: 24000 Hz or 48000 Hz; - 24-bit precision, WAV format; - Recording time is unlimited until memory is full (when recording continuously, the recording files are split into one file per hour); - Recordings can be played back on the device or on a PC;
Voice coments
Yes
Hardware Features
Number of Channels
1
Microphone Type
ZX 1025
Preamplifier Type
ZX 1901L (LEMO connector)
Bluetooth
Yes
GPS
None
Display
4.3 inch, resolution:480x800, Touch Screen
Data Interface
4G, WIFI, Bluetooth, IO Protocol, USB-C
Data Storage
16GB internal (up to 64 GB TF Card)
Power (Basic Functions)
2W ~ 6W
Battery
One 3.7 V 10000 mAh lithium battery, 9 VDC external power supply (20 W fast charge), charges fully within 5 hours; up to 28 hours;
Calendar Clock
Monthly error less than 1 minute with the battery
Operating time
up to 28 hours
Operating temperature range
-20 °C〜60 °C
Humidity range
20 %〜90 %
Atmospheric pressure
65 kPa〜108 kPa
Weight
Approx. 510g
Overall dimensions (mm):
288×95×40
  • Linkedin

Get in touch

2570 N First St, 2nd Floor

San Jose, CA 95131

United States

+1 (408) 320-5333

+1 (570) 599-6642

bottom of page