Standards | |
---|---|
Class 1:IEC 61672-1:2013;
| |
Class 1:IEC 61260-1:2014; | |
IEC 61252:2017 |
Applications |
---|
Sound Measurements |
Environmental Noise |
Occupational Noise |
Building Acoustics |
Sound Measurements Features | |
---|---|
Total Measurement range | 20 dB(A)〜143 dB(A); 25 dB(C)〜143 dB (C); 30 dB(Z)〜143 dB (Z) |
Internal noise | < 18 dB(A) Leq
|
microphone and preamplifier sensitivity | -28 dB
Note: Sensitivity is referenced at 0 dB with 1V/Pa. Unless otherwise specified below, all references to sensitivity pertain to the standard configuration. |
Frequency range | 10 Hz~20 kHz
|
Weighting filters | Parallel A, C, Z weighting |
Time constants | Parallel F (fast), S (slow), I (impulse) |
Exchange rates | 3, 4, 5, 6 |
Measurement Time | 1 second to 96 hours |
Total value integration | Peak C Sound Level Measurement Range: 60 dB~146 dB
Measurement Indicators: Lxyp, Lxeq,t, Lxeq,T, Lxmax, Lxmin, LxN, Lxpeak, SEL, SD
Note: x represents A, C, Z; y represents F, S, I; N represent5,10, 50, 90, 95
|
Statistics (Optional) | Analysis Mode: Single, 24hours.
Statistical Analysis Indicators: Lxyp, Lxeq,T, Lxmax, Lxmin, LxN, SD, SEL.
24h Mode Analysis Indicators: Lxyinst, Lxeq,T, Lxmax, Lxmin, LxN, SD, SEL, Ld, Ln, Ldn;
Note 1: x represents A, C, Z; y represents F, S, I; N represents 5, 10, 50, 90, 95(customize up to 10 values between 1 to 99) |
1/1 octave (Optional) | Filter Type: Parallel (real-time) octave, G=10^(3/10).
Complies with Standards: Class 1: IEC 61260:1995, MOD;
Filter Center Frequencies: From 8 Hz up to 16 kHz
Time Weighting: Fast (F) and Slow (S).
Real-time Analysis: Parallel computation of all center frequencies with A, C, Z weightings.
Dynamic Range: Greater than 90 dB (Z).
Main Measurement Indicators: Instantaneous Sound Pressure Level (Lp) in bands, Maximum (Max), Minimum (Min), and Equivalent Continuous Sound Pressure Level (Leq,T). |
1/3 octave (Optional) | Filter Type: Parallel (real-time) one-third octave, G=10^(3/10).
Complies with Standards: Class 1: IEC 61260:1995, MOD;
Filter Center Frequencies: From 5 Hz up to 20 kHz.
Time Weighting: Fast (F) and Slow (S).
Real-time Analysis: Parallel computation of all center frequencies with A, C, Z weightings, including custom frequency weightings.
Dynamic Range: Greater than 90 dB (Z).
Main Measurement Indicators: Instantaneous Sound Pressure Level (Lp) in bands, Maximum (Max), Minimum (Min), and Equivalent Continuous Sound Pressure Level (Leq,T). |
FFT (Optional) | Pre-FFT Weighting: A, C, Z weightings.
Time Weighting: Fast (F) and Slow (S), optional.
FFT Analysis Lines: up to 3385 lines.
Analysis Frequency Upper Limit: up to 20k Hz
Bandwidth per Line Bp: 5.9 Hz
Window Functions: Flat-top, Hanning, and Rectangular windows selectable.
Measurement Indicators: Fast time-weighted instantaneous values under each spectrum line, slow time-weighted instantaneous values, maximum and minimum sound pressure levels (Max/Min) under the spectrum line, and equivalent continuous sound pressure level (Leq,T), with measurement duration (Tm). |
Reverberation time (Optional) | ISO 3382-2:2008; |
STIPA (Optional) | - IEC 60268-16;ISO 3382-1; ISO 3382-2; ISO 3382-3; ISO 1996;
- Measurement Indices:Leq、MTI、STI;
- Single Record Time:15 s;
- Recording Precision: Sampling rate 48 kHz, 32-bit;
- Frequency Points: 125 Hz, 250 Hz, 500 Hz, 1000 Hz, 2000 Hz, 4000 Hz, 8000 Hz; |
Audio recording | - Selectable Sampling Rates: 24000 Hz or 48000 Hz;
- 24-bit precision, WAV format;
- Recording time is unlimited until memory is full (when recording continuously, the recording files are split into one file per hour);
- Recordings can be played back on the device or on a PC; |
Voice coments | Yes |
Hardware Features | |
---|---|
Number of Channels | 1 |
Microphone Type | ZX 1025 |
Preamplifier Type | ZX 1901L (LEMO connector) |
Bluetooth | Yes |
GPS | None |
Display | 4.3 inch, resolution:480x800, Touch Screen |
Data Interface | 4G, WIFI, Bluetooth, IO Protocol, USB-C |
Data Storage | 16GB internal (up to 64 GB TF Card) |
Power (Basic Functions) | 2W ~ 6W |
Battery | One 3.7 V 10000 mAh lithium battery, 9 VDC external power supply (20 W fast charge), charges fully within 5 hours; up to 28 hours; |
Calendar Clock | Monthly error less than 1 minute with the battery |
Operating time | up to 28 hours |
Operating temperature range | -20 °C〜60 °C |
Humidity range | 20 %〜90 % |
Atmospheric pressure | 65 kPa〜108 kPa |
Weight | Approx. 510g |
Overall dimensions (mm): | 288×95×40 |