Hardware Features | |
---|---|
Number of Channels | 1 |
Microphone Type | Class 1: ZX1025
Class 2: ZX1021B |
Preamplifier Type | ZX 1901L (LEMO connector) |
Bluetooth | Optional(Data Transfer,Printer) |
GPS | N/A |
Display | 3.5 inch, 240x320 resolution |
Data Interface | RS232, USB, DC signal, AC signal, Bluetooth, DTU |
Memory | TF card, 32GB |
Data Storage | 32 MB Flash RAM |
Other Storage | 5 sets of parameter templates, 64 measurement points, 256 calibration records |
Power (Basic Functions) | <90 mA/5 V |
Battery Type | --4 AA alkaline batteries: Continues operation over 30 hours under basic functions;
--Optional lithium battery: 7.4 V/2 AH, continuous operation over 30 h;
--External power supply: 5 V/1 A, USB Type-C port. |
Calendar Clock | Monthly error less than 1 minute |
Operating time | > 30 hours |
Operating temperature range | -10 °C〜50 °C |
Humidity range | 25 %〜90 % |
Atmospheric pressure | 65 kPa〜108 kPa |
Weight | Approx. 350g |
Overall dimensions (mm): | 285×85×30 |
Sound Measurements Features | |
---|---|
Total Measurement range | Class1: 18 dB(A)〜144 dB(A); 30 dB(C)〜144 dB (C); 40 dB(Z)〜144 dB (Z) |
Class2: 25 dB(A)〜144 dB(A); 35 dB(C)〜144 dB (C); 45 dB(Z)〜144 dB (Z) | |
Internal noise | Class1: < 13 dBA Leq; 20dBC Leq; <27dB(Z) Leq
|
Class2: < 18 dBA Leq; 25dBC Leq; <30dB(Z) Leq
| |
microphone and preamplifier sensitivity | -36 dB
Note: Sensitivity is referenced at 0 dB with 1V/Pa. Unless otherwise specified below, all references to sensitivity pertain to the standard configuration. |
Frequency range | Class 1: 10 Hz~20 kHz
Class 2: 20 Hz~12.5 kHz |
Weighting filters | Parallel A, C, Z weighting |
Time constants | Parallel F (fast), S (slow), I (impulse) |
Exchange rates | 3, 4, 5, 6 |
Total value integration | Peak C Sound Level Measurement Range: 60 dB~146 dB
Main Measurement Indicators: Lxyi, Lxyp, Lxeq,t, Lxeq,T, Lxmax, Lxmin, Lxpeak, LAE, LC-A, SEL
Note: x represents A, C, Z; y represents F, S, I
|
Statistics | Number of Modules: 2.
Analysis Mode: Single or 24hours option.
Statistical Analysis Indicators: Lxyi, Lxyp, Lxeq,T, Lxmax, Lxmin, LxN, SD, SEL.
24h Mode Analysis Indicators: Lxyi, Lxyp, Lxeq,T, Lxmax, Lxmin, LxN, SD, SEL, Ld, Ln, Ldn, etc.
Note 1: x represents A, C, Z; y represents F, S, I; N represents 5, 10, 50, 90, 95
Note 2: When Ln is activated, 7 additional statistical indicators are added |
Measurement Time | 1 second to 24 hours |
1/1 octave | Filter Type: Parallel (real-time) octave, G=103/10.
Complies with Standards:
Filter Center Frequencies:
--Class 1: 16 Hz, 31.5 Hz, 63 Hz, 125 Hz, 250 Hz, 500 Hz, 1 kHz, 2 kHz, 4 kHz, 8 kHz, 16 kHz.
--Class 2: 31.5 Hz, 63 Hz, 125 Hz, 250 Hz, 500 Hz, 1 kHz, 2 kHz, 4 kHz, 8 kHz
Time Weighting: Fast (F) and Slow (S).
Real-time Analysis: Parallel computation of all center frequencies with A, C, Z weightings.
Dynamic Range: Greater than 100 dB (Z).
Main Measurement Indicators: Instantaneous Sound Pressure Level (Lp) in bands, Maximum (Max), Minimum (Min), and Equivalent Continuous Sound Pressure Level (Leq,T), Noise Rating (NR). |
1/3 octave | Filter Type: Parallel (real-time) one-third octave, G=103/10.
Complies with Standards:
Filter Center Frequencies:
--Class 1: From 12.5 Hz up to 25 kHz.
--Class 2: From 20 Hz up to 12.5 kHz.
Time Weighting: Fast (F) and Slow (S).
Real-time Analysis: Parallel computation of all center frequencies with A, C, Z weightings, including custom frequency weightings.
Dynamic Range: Greater than 100 dB (Z).
Main Measurement Indicators: Instantaneous Sound Pressure Level (Lp) in bands, Maximum (Max), Minimum (Min), and Equivalent Continuous Sound Pressure Level (Leq,T). |
FFT | Pre-FFT Weighting: A, C, Z weightings.
Time Weighting: Fast (F) and Slow (S), optional.
FFT Analysis Lines: 2048 lines.
Analysis Frequency Upper Limit:
--Class 1: 28640 Hz、14320 Hz、7160 Hz、3580 Hz、1790 Hz.
--Class 2: 14320 Hz、7160 Hz、3580 Hz、1790 Hz、895 Hz.
Bandwidth per Line Bp:
--Class 1: From 32 Hz down to 2 Hz.
--Class 2: From 16 Hz down to 1 Hz.
Window Functions: Flat-top, Bruhn, Hanning, and Tectangular windows selectable.
Measurement Indicators: Fast time-weighted instantaneous values under each spectrum line, slow time-weighted instantaneous values, maximum and minimum sound pressure levels (Max/Min) under the spectrum line, and equivalent continuous sound pressure level (Leq,T), with measurement duration (Tm). |
Reverberation time(RT60) | Optional |
STIPA | N/A |
Audio recording | Saved in to TF card |
Voice comments | N/A |
Standards |
---|
Class 1:IEC 61672-1:2013;
|
Class 1:IEC 61260-1:2014; |
Applications
|
---|
Sound Measurements |
Environmental Noise |
Occupational Noise |
Building Acoustics |