top of page

Home / Solutions / ZX9920

ZX9920

Wireless Architectural Acoustics Measurement System

The ZX9920 Wireless Architectural Acoustics Measurement System is an integrated solution for field measurement and assessment of  acoustic performance.

The system combines wireless data acquisition units, standardized acoustic sources, Class 1 measurement instrumentation and dedicated architectural acoustics software. Wireless communication between measurement rooms reduces cable routing, improves test efficiency and simplifies multi-room measurements.

The ZX9920 supports two-channel and four-channel configurations for residential buildings, commercial properties, laboratories, educational facilities and acoustic consulting applications.

ZX9920.png

​System Overview

Key Applications

Building Sound Insulation

  • Airborne sound insulation between rooms

  • Internal wall and partition testing

  • Floor and ceiling airborne sound insulation

  • Façade and external wall sound insulation

  • Door and window sound insulation

  • Room-to-room sound isolation

Impact Sound Insulation

  • Floor impact sound insulation

  • Floor-ceiling assembly assessment

  • Standard tapping machine measurements

  • Rubber impact ball measurements

  • Low-frequency impact sound evaluation

Room Acoustics

  • Reverberation time

  • Sound decay measurements

  • Background noise

  • Room-to-room level differences

  • Building services noise

  • Indoor environmental noise

Core Advantages

Wireless Measurement Architecture

​Wireless acquisition units allow measurement channels to be positioned in separate rooms without long signal cables.

This reduces installation time and improves measurement efficiency in occupied buildings and completed construction projects.

Two-Channel and Four-Channel Configurations

The system is available in flexible two-channel and four-channel versions.

Multiple wireless measurement units can be connected simultaneously for synchronized measurements at different positions.

Portable and Field-Ready

​Compact instruments, wireless communication and battery-powered operation make the system suitable for field measurements.

The complete system can be transported between different rooms, buildings and project sites.

Integrated Measurement Workflow

The ZX9920 supports the complete architectural acoustics measurement process:

  • Source-room sound level measurement

  • Receiving-room sound level measurement

  • Background-noise correction

  • Reverberation-time correction

  • Frequency-band analysis

  • Single-number rating calculation

  • Automated report generation

Guided Software Operation

The dedicated measurement software provides guided workflows, standardized test procedures and automatic data processing.

New users can follow step-by-step instructions, while experienced consultants can access advanced measurement and reporting functions.

Measurement Methods

Guided Software Operation

The system measures sound levels in the source room and receiving room and applies background-noise and reverberation corrections.

Supported applications include:

  • Room-to-room airborne sound insulation

  • Wall and partition performance

  • Floor and ceiling airborne sound insulation

  • Façade sound insulation

  • Door and window sound insulation

Typical reported quantities may include:

  • Apparent sound reduction index

  • Standardized level difference

  • Normalized level difference

  • Weighted sound insulation ratings

  • Spectrum adaptation terms

Impact Sound Insulation

The ZX9920 supports standardized floor impact testing using a tapping machine or optional rubber impact ball.

The measurement system records impact sound levels in the receiving room and applies the required corrections and rating calculations.

Typical applications include:

  • Floor-ceiling assembly testing

  • Residential floor impact assessment

  • Comparison of floor covering systems

  • Evaluation of resilient layers

  • Construction quality verification

Reverberation Time

Reverberation time can be measured using:

  • Interrupted-noise method

  • Integrated impulse-response method

  • MLS-based measurement mode, where permitted by the selected procedure

The software automatically calculates decay curves and reverberation-time results across the selected frequency range.

Measurement Methods

Reverberation Time

The system measures sound levels in the source room and receiving room and applies background-noise and reverberation corrections.

Supported applications include:

  • Room-to-room airborne sound insulation

  • Wall and partition performance

  • Floor and ceiling airborne sound insulation

  • Façade sound insulation

  • Door and window sound insulation

Typical reported quantities may include:

  • Apparent sound reduction index

  • Standardized level difference

  • Normalized level difference

  • Weighted sound insulation ratings

  • Spectrum adaptation terms

Impact Sound Insulation

The ZX9920 supports standardized floor impact testing using a tapping machine or optional rubber impact ball.

The measurement system records impact sound levels in the receiving room and applies the required corrections and rating calculations.

Typical applications include:

  • Floor-ceiling assembly testing

  • Residential floor impact assessment

  • Comparison of floor covering systems

  • Evaluation of resilient layers

  • Construction quality verification

Reverberation Time

Reverberation time can be measured using:

  • Interrupted-noise method

  • Integrated impulse-response method

  • MLS-based measurement mode, where permitted by the selected procedure

The software automatically calculates decay curves and reverberation-time results across the selected frequency range.

Advanced MLS Measurement Option

Efficient Measurement in Real-World Conditions

The optional MLS-based measurement mode uses digitally generated test signals and signal processing to obtain room impulse-response and sound decay information.

Compared with conventional methods, MLS measurement can provide several practical benefits:

  • Improved resistance to steady background noise

  • Faster room-acoustics measurements

  • Improved signal-to-noise ratio

  • Reduced source power requirements

  • Broader useful measurement range

  • Better repeatability in difficult test environments

MLS measurement is particularly useful for rapid reverberation-time measurements and low-level receiving-room conditions, where permitted by the selected standard and project procedure.

Standards Support

International Standards

The ZX9920 is designed to support measurements and calculations based on applicable architectural acoustics standards, including:

Field Measurement Methods

ISO 16283-1

Acoustics — Field measurement of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation

ISO 16283-2:2020

Part 2: Impact sound insulation 

ISO 16283-3:2016

Part 3: Façade sound insulation 

ISO 3382-2

 Reverberation time in ordinary rooms

Rating Standards

ISO 717-1:2020

 Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation

ISO 717-2 / AS ISO 717.2

Supports measurements required for Australian building-acoustics assessment, subject to the applicable NCC edition, project specification and adopted test standard.

Australian Applications

The ZX9920 can be configured for architectural acoustics measurements according to applicable Australian, adopted ISO and project-specific requirements.

Typical applications include:

  • Residential wall and floor sound insulation

  • Apartment separation testing

  • Façade sound insulation

  • Floor impact sound assessment

  • Reverberation-time measurement

  • Building code and project acceptance testing

Typical reported quantities may include:

​​​​

Relevant Australian references may include adopted ISO 717 standards and applicable AS or AS/NZS field measurement methods.

Supports interrupted-noise and integrated-impulse-response measurement methods, depending on the selected standard and software configuration.

bottom of page