Home / Solutions / ZX9920
ZX9920
Wireless Architectural Acoustics Measurement System
The ZX9920 Wireless Architectural Acoustics Measurement System is an integrated solution for field measurement and assessment of acoustic performance.
The system combines wireless data acquisition units, standardized acoustic sources, Class 1 measurement instrumentation and dedicated architectural acoustics software. Wireless communication between measurement rooms reduces cable routing, improves test efficiency and simplifies multi-room measurements.
The ZX9920 supports two-channel and four-channel configurations for residential buildings, commercial properties, laboratories, educational facilities and acoustic consulting applications.

System Overview
Key Applications
Building Sound Insulation
-
Airborne sound insulation between rooms
-
Internal wall and partition testing
-
Floor and ceiling airborne sound insulation
-
Façade and external wall sound insulation
-
Door and window sound insulation
-
Room-to-room sound isolation
Impact Sound Insulation
-
Floor impact sound insulation
-
Floor-ceiling assembly assessment
-
Standard tapping machine measurements
-
Rubber impact ball measurements
-
Low-frequency impact sound evaluation
Room Acoustics
-
Reverberation time
-
Sound decay measurements
-
Background noise
-
Room-to-room level differences
-
Building services noise
-
Indoor environmental noise
Core Advantages
Wireless Measurement Architecture
Wireless acquisition units allow measurement channels to be positioned in separate rooms without long signal cables.
This reduces installation time and improves measurement efficiency in occupied buildings and completed construction projects.
Two-Channel and Four-Channel Configurations
The system is available in flexible two-channel and four-channel versions.
Multiple wireless measurement units can be connected simultaneously for synchronized measurements at different positions.
Portable and Field-Ready
Compact instruments, wireless communication and battery-powered operation make the system suitable for field measurements.
The complete system can be transported between different rooms, buildings and project sites.
Integrated Measurement Workflow
The ZX9920 supports the complete architectural acoustics measurement process:
-
Source-room sound level measurement
-
Receiving-room sound level measurement
-
Background-noise correction
-
Reverberation-time correction
-
Frequency-band analysis
-
Single-number rating calculation
-
Automated report generation
Guided Software Operation
The dedicated measurement software provides guided workflows, standardized test procedures and automatic data processing.
New users can follow step-by-step instructions, while experienced consultants can access advanced measurement and reporting functions.
Measurement Methods
Guided Software Operation
The system measures sound levels in the source room and receiving room and applies background-noise and reverberation corrections.
Supported applications include:
-
Room-to-room airborne sound insulation
-
Wall and partition performance
-
Floor and ceiling airborne sound insulation
-
Façade sound insulation
-
Door and window sound insulation
Typical reported quantities may include:
-
Apparent sound reduction index
-
Standardized level difference
-
Normalized level difference
-
Weighted sound insulation ratings
-
Spectrum adaptation terms
Impact Sound Insulation
The ZX9920 supports standardized floor impact testing using a tapping machine or optional rubber impact ball.
The measurement system records impact sound levels in the receiving room and applies the required corrections and rating calculations.
Typical applications include:
-
Floor-ceiling assembly testing
-
Residential floor impact assessment
-
Comparison of floor covering systems
-
Evaluation of resilient layers
-
Construction quality verification
Reverberation Time
Reverberation time can be measured using:
-
Interrupted-noise method
-
Integrated impulse-response method
-
MLS-based measurement mode, where permitted by the selected procedure
The software automatically calculates decay curves and reverberation-time results across the selected frequency range.
Measurement Methods
Reverberation Time
The system measures sound levels in the source room and receiving room and applies background-noise and reverberation corrections.
Supported applications include:
-
Room-to-room airborne sound insulation
-
Wall and partition performance
-
Floor and ceiling airborne sound insulation
-
Façade sound insulation
-
Door and window sound insulation
Typical reported quantities may include:
-
Apparent sound reduction index
-
Standardized level difference
-
Normalized level difference
-
Weighted sound insulation ratings
-
Spectrum adaptation terms
Impact Sound Insulation
The ZX9920 supports standardized floor impact testing using a tapping machine or optional rubber impact ball.
The measurement system records impact sound levels in the receiving room and applies the required corrections and rating calculations.
Typical applications include:
-
Floor-ceiling assembly testing
-
Residential floor impact assessment
-
Comparison of floor covering systems
-
Evaluation of resilient layers
-
Construction quality verification
Reverberation Time
Reverberation time can be measured using:
-
Interrupted-noise method
-
Integrated impulse-response method
-
MLS-based measurement mode, where permitted by the selected procedure
The software automatically calculates decay curves and reverberation-time results across the selected frequency range.
Advanced MLS Measurement Option
Efficient Measurement in Real-World Conditions
The optional MLS-based measurement mode uses digitally generated test signals and signal processing to obtain room impulse-response and sound decay information.
Compared with conventional methods, MLS measurement can provide several practical benefits:
-
Improved resistance to steady background noise
-
Faster room-acoustics measurements
-
Improved signal-to-noise ratio
-
Reduced source power requirements
-
Broader useful measurement range
-
Better repeatability in difficult test environments
MLS measurement is particularly useful for rapid reverberation-time measurements and low-level receiving-room conditions, where permitted by the selected standard and project procedure.
Standards Support
International Standards
The ZX9920 is designed to support measurements and calculations based on applicable architectural acoustics standards, including:
Field Measurement Methods
ISO 16283-1
Acoustics — Field measurement of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation
ISO 16283-2:2020
Part 2: Impact sound insulation
ISO 16283-3:2016
Part 3: Façade sound insulation
ISO 3382-2
Reverberation time in ordinary rooms
Rating Standards
ISO 717-1:2020
Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation
ISO 717-2 / AS ISO 717.2
Supports measurements required for Australian building-acoustics assessment, subject to the applicable NCC edition, project specification and adopted test standard.
Australian Applications
The ZX9920 can be configured for architectural acoustics measurements according to applicable Australian, adopted ISO and project-specific requirements.
Typical applications include:
-
Residential wall and floor sound insulation
-
Apartment separation testing
-
Façade sound insulation
-
Floor impact sound assessment
-
Reverberation-time measurement
-
Building code and project acceptance testing
Typical reported quantities may include:
Relevant Australian references may include adopted ISO 717 standards and applicable AS or AS/NZS field measurement methods.
Supports interrupted-noise and integrated-impulse-response measurement methods, depending on the selected standard and software configuration.